If you make any non-trivial changes to the Pirahna 1060 or perform maintenance please note it here, delete records older than 1 yr
If you make any non-trivial changes to the Pirahna 1060 or perform maintenance please note it here, delete records older than 1 yr


* Laser checked and realigned, dust system cleaned and potential leak fixed, bed levelled, thorough cleaning. Laser tube is showing parasitic CEM mode and anticipate replacement needed this year. [[User:Stever|Stever]] ([[User talk:Stever|talk]]) 15:26, 20 August 2021 (BST)
* Clean lens and Mirrors 2&3, all in good condition. Change spacer block to correct size, check airflow (reduced to 1.2m/s but still OK) [[User:Stever|Stever]] ([[User talk:Stever|talk]]) 22:14, 28 July 2021 (BST)
* Clean lens and Mirrors 2&3, all in good condition. Change spacer block to correct size, check airflow (reduced to 1.2m/s but still OK) [[User:Stever|Stever]] ([[User talk:Stever|talk]]) 22:14, 28 July 2021 (BST)
* Realigned due to poor cutting. Mirror 2 angled too far left, so almost completely missing the housing. Also the actual main laser tube is now slightly too high. Didn't change as this will require a full moving out of the entire machine, so I've averaged out the error as best I can for now, but will need doing soon. [[User:Ruperte|Ruperte]] ([[User talk:Ruperte|talk]]) 23:20, 4 July 2021 (BST)
* Realigned due to poor cutting. Mirror 2 angled too far left, so almost completely missing the housing. Also the actual main laser tube is now slightly too high. Didn't change as this will require a full moving out of the entire machine, so I've averaged out the error as best I can for now, but will need doing soon. [[User:Ruperte|Ruperte]] ([[User talk:Ruperte|talk]]) 23:20, 4 July 2021 (BST)