* Lens replaced, some signs of dust in the air system, possibly polypropylene makes dust fine enough to pass filter? [[User:Stever|Stever]] ([[User talk:Stever|talk]]) 21:56, 16 June 2021 (BST) |
* Lens replaced, some signs of dust in the air system, possibly polypropylene makes dust fine enough to pass filter? [[User:Stever|Stever]] ([[User talk:Stever|talk]]) 21:56, 16 June 2021 (BST) |
||
* Laser intermittently not firing or stopping mid job. Switch 3 on side replaced, and HT PSU enable relay found to have bad contacts. so replaced, now working normally [[User:Ruperte|Ruperte]] ([[User talk:Ruperte|talk]]) 14:24, 1 June 2021 (BST) |
* Laser intermittently not firing or stopping mid job. Switch 3 on side replaced, and HT PSU enable relay found to have bad contacts. so replaced, now working normally [[User:Ruperte|Ruperte]] ([[User talk:Ruperte|talk]]) 14:24, 1 June 2021 (BST) |
||
* Deep clean |
* Deep clean bed and inside of machine. Re-lube Z-Axis leadscrews. Test water pump for leaks. [[User:Jmf|Jmf]] ([[User talk:Jmf|talk]]) 20:17, 10 April 2021 (BST) |
||
* Fully enable Z-height control functions to allow multi-depth engraving [[User:Stever|Stever]] ([[User talk:Stever|talk]]) 14:44, 16 November 2020 (UTC) |
* Fully enable Z-height control functions to allow multi-depth engraving [[User:Stever|Stever]] ([[User talk:Stever|talk]]) 14:44, 16 November 2020 (UTC) |
||
* Clean and re-lubricate linear bearings [[User:Stever|Stever]] ([[User talk:Stever|talk]]) 10:52, 9 November 2020 (UTC) |
* Clean and re-lubricate linear bearings [[User:Stever|Stever]] ([[User talk:Stever|talk]]) 10:52, 9 November 2020 (UTC) |