| 31st October 2020 || Very poor cutting quality || Beam alignment is very badly degraded, only very thin materials can be cut effectively.
| 9th November 2020 || Fully functional || Beam re-alignment done
|}
|}


Line 168: Line 168:
If you make any non-trivial changes to the Pirahna 1060 or perform maintenance please note it here, delete records older than 1 yr
If you make any non-trivial changes to the Pirahna 1060 or perform maintenance please note it here, delete records older than 1 yr


* Deep clean, service, change air and water filters, rough re-alignment [[User:Stever|Stever]] ([[User talk:Stever|talk]]) 10:50, 9 November 2020 (UTC)
* Clean and re-lubricate linear bearings [[User:Stever|Stever]] ([[User talk:Stever|talk]]) 10:52, 9 November 2020 (UTC)
* Deep clean, service, change air and water filters, rough re-alignment [[User:Stever|Stever]] ([[User talk:Stever|talk]]), [[User:Jmf|Jmf]] ([[User talk:Jmf|talk]]), Rupert & Tony 10:50, 4 November 2020 (UTC)
* Deep clean bed and inside of machine. Re-lube the Z-Axis leadscrews. [[User:Jmf|Jmf]] ([[User talk:Jmf|talk]]) 12:03, 17 October 2020 (BST)
* Deep clean bed and inside of machine. Re-lube the Z-Axis leadscrews. [[User:Jmf|Jmf]] ([[User talk:Jmf|talk]]) 12:03, 17 October 2020 (BST)
* Replace HV power switch [[User:Stever|Stever]] ([[User talk:Stever|talk]]) 18:32, 1 October 2020 (BST)
* Replace HV power switch [[User:Stever|Stever]] ([[User talk:Stever|talk]]) 18:32, 1 October 2020 (BST)